HR: 1340h
AN: B13A-0892 [Abstracts]
TI: MPI-DING Reference Glasses for in-situ Isotope Analysis and the GeoReM Database
AU: * Jochum, K P
EM: kpj@mpch-mainz.mpg.de
AF: Max-Planck-Institut fuer Chemie, Postfach 3060, Mainz, 55020, Germany
AB:
Microanalytical techniques, such as LA-ICPMS, LA-MC-ICPMS, SIMS, have become important tools for in-situ
isotope analysis. Yet, the lack of widely available geological reference glasses has made interlaboratory
comparisons and assessment of analytical accuracy difficult or even impossible in many cases. Jochum et al.
(2000) prepared eight geological MPI-DING glasses of different natural composition (from ultramafic to highly
siliceous composition) for the purpose of providing reference materials for in-situ microanalytical work. Recently,
reference values for up to 74 major and trace elements have been determined following the recommendations of
the IAG (Jochum et al., 2006).
The isotopic composition of H, Li, B, O, Ca, Sr, Nd, Hf and Pb was determined in the MPI-DING reference glasses
by high-precision mass spectrometric (e.g., TIMS, MC-ICPMS) using large sample amounts and by
microanalytical (LA-ICPMS, LA-MC-ICPMS, SIMS) techniques. The precision of the bulk techniques is significantly
higher than that of the microanalytical techniques. However, the microanalytical techniques have the advantage of
high spatial resolution and fast sample preparation.
The boron isotope composition was determined using TIMS and LA-MC-ICPMS. LA-MC-ICPMS data for the MPI-
DING glasses agree with the TIMS data at the 2 σ level. The MPI-DING glasses range from δ 7Li of
2.0 to 17.1 ‰ LSVEC. The uncertainties of MC-ICPMS measurements compared to SIMS data are
smaller, owing to the larger amount of Li measured. Some small local heterogeneity in Li isotopes could be
observed using SIMS.
Highly precise Sr and Nd isotope analyses were performed for each MPI-DING glass using TIMS. Recently, Sr
isotopes have also been determined by LA-ICPMS in the low-Sr (30 - 300 ppm) glasses. The 87Sr/86Sr ratios for
KL2-G (0.7038 ± 0.0002), ML3B-G (0.7035 ± 0.0003) and GOR128-G (0.7067 ± 0.0007) agree
within 0.01 - 0.04 % with the TIMS data.
Lead isotope ratios have been determined by TIMS, MC-ICPMS, solution ICPMS and LA-ICPMS. LA-ICPMS is able
to determine 208Pb/206Pb and 207Pb/206Pb ratios in the low-Pb (1 - 10 ppm) MPI-DING glasses with a
precision of about 0.05 - 0.2%. Possible heterogeneities of Pb isotopes are found by high-precision TIMS and
MC-ICPMS measurements using different glass chips. However, the differences are lower than the reproducibility
obtained from microanalytical techniques.
Because the amount of data for reference materials has significantly increased in recent years, there is a need for
a database that contains published analytical data together with important metadata (e.g., uncertainty, analytical
technique, laboratory) in a form in which it can be accessed readily by geochemists. Jochum et al. (2005) have
therefore developed the GeoReM database (http://georem.mpch-mainz.gwdg.de) for reference materials and
isotopic standards of geochemical, mineralogical and environmental interest. At present, GeoReM contains ca.
1500 reference materials (including the MPI-DING glasses) and 13500 analyses from about 2100 publications.
DE: 1040 Radiogenic isotope geochemistry
DE: 1041 Stable isotope geochemistry (0454, 4870)
DE: 1065 Major and trace element geochemistry
SC: Biogeosciences [B]
MN: 2007 Fall Meeting