HR: 1340h
AN: B13A-0893 [Abstracts]
TI: A Laser-Extraction Technique for Oxygen Isotope Analysis of Diatom Frustules
AU: * Dodd, J P
EM: jpd829@unm.edu
AF: University of New Mexico, Department of Earth and Planetary Sciences MSC03-2040 1
University of New Mexico, Albuquerque, NM 87131, United States
AU: Sharp, Z D
EM: zsharp@unm.edu
AF: University of New Mexico, Department of Earth and Planetary Sciences MSC03-2040 1
University of New Mexico, Albuquerque, NM 87131, United States
AU: Fawcett, P J
EM: fawcett@unm.edu
AF: University of New Mexico, Department of Earth and Planetary Sciences MSC03-2040 1
University of New Mexico, Albuquerque, NM 87131, United States
AU: Schiff, C
EM: caleb.schiff@nau.edu
AF: Department of Geology, Northern Arizona University, PO Box 4099, Flagstaff, AZ 86011,
United States
AU: Kaufman, D S
EM: darrell.kaufman@nau.edu
AF: Department of Geology, Northern Arizona University, PO Box 4099, Flagstaff, AZ 86011,
United States
AB:
Biogenic opal in the form of diatom frustules is abundant in lacustrine and marine environments throughout the
Cenozoic. Oxygen isotope ratios preserved in the SiO2 of diatom frustules provide a valuable archive of
paleoclimatic data, such as changes in temperature and precipitation/evaporation. However, oxygen isotope
analysis of diatom silica is complicated by the presence of >15 wt. % H2 O that must be removed prior
to analysis for accurate δ18Odiatom measurements to be obtained. Various techniques have
been used to remove the hydrous silica including vacuum dehydration, isotope exchange, and stepwise
fluorination. Here we present a laser-extraction technique for oxygen isotope analysis of biogenic opal that is
rapid and requires far less material than other techniques. Batches of approximately twenty 1 to 2 mg aliquots of
pure diatoms are loaded in a laser chamber and pre-fluorinated with F2 gas, similarly to previously
published stepwise fluorination techniques to remove the hydrous portion of biogenic silica. The remaining
SiO2 is then volatilized in the presence of BrF5 with a CO2 laser to produce O2 gas. The
δ18Odiatom values produced through the laser-extraction technique increase with increasing
pre-fluorination times as the hydrous portion of the silica is removed. A plateau with a constant, reproducible
δ18O value is obtained once all of the hydrous silica is removed. The diatoms samples analyzed in
this study are from sediments collected from the Valles Caldera in New Mexico, USA, and consist of a coarse
(>50 micron) and fine (<50 micron) size samples from different locations in the caldera. Two different coarse
grained samples were analyzed using the laser-extraction technique and had δ18Odiatom
values that range from 31.2 to 32.4 ‰ and 31.6 to 32.5 ‰. In these samples values plateaued at
32.3 (±0.1) ‰ and 32.2 (±0.2) ‰. A finer grained sample, also from the Valles Caldera,
had δ18Odiatom values that ranged from 28.5 to 29.0 ‰ and plateaued at 28.7 ‰
(±0.2). Additional diatom samples used in this study came from a variety of modern and ancient lacustrine
and marine sources and were used to compare the laser extraction technique with other techniques.
δ18Odiatom values obtained with laser extraction are 2 to 4 ‰ higher than
δ18Odiatom values obtained using conventional vacuum dehydration of the same samples,
suggesting that there is more complete removal of the hydrous material with the laser extraction technique or
less exchange of the hydrous component during dehydration. Reproducibility of δ18Odiatom
values obtained by the laser-extraction technique is ± 0.2 ‰. We propose that the laser-extraction
technique for obtaining oxygen isotope values from diatom silica has advantages over other techniques in terms
of sample size, removal of the hydrous material, and analytical procedure.
DE: 0454 Isotopic composition and chemistry (1041, 4870)
DE: 1694 Instruments and techniques
DE: 3305 Climate change and variability (1616, 1635, 3309, 4215, 4513)
DE: 4820 Gases
DE: 4870 Stable isotopes (0454, 1041)
SC: Biogeosciences [B]
MN: 2007 Fall Meeting