HR: 0800h
AN: H41A-0132 [Abstracts]
TI: Adjustment Needed for Helley-Smith Bedload Samples Collected at low Transport Rates on Coarse Gravel Beds
AU: * Bunte, K
EM: kbunte@engr.colostate.edu
AF: Colorado State University, Engineering Research Center, Fort Collins, CO 80523, United
States
AU: Swingle, K W
EM: kskb@ix.netcom.com
AF: Independent Researcher, 630 Iris Ave., Boulder, CO 80304, United States
AU: Abt, S R
EM: sabt@engr.colostate.edu
AF: Colorado State University, Engineering Research Center, Fort Collins, CO 80523, United
States
AB:
River restoration frequently requires measurements of bedload transport as part of a site specific rating curve or
as input for model calibration. A Helley-Smith type (HS) sampler is commonly used for these measurements, but
it can have biased results. Several studies have shown that HS samplers deployed directly on a coarse gravel
bed interact with the bed sediment. The interaction may take the form of perching on top of large particles (which
prevents collection of particles moving in close contact with the bed), dislocating and scooping pebbles, creating
scour around the sampler, and sucking sediment into the sampler due to a hydraulic efficiency >1. This
interaction can lead to an assessment of transport rates that are either too high or too low. By contrast, studies
that deployed a HS sampler on a sill report good correspondence with transport rates collected using other
devices. This study examined whether elimination of direct bed contact with a HS sampler improves its sampling
accuracy.
Paired bedload samples were collected (either simultaneously or immediately following each other) with a 3-
inch, thin-walled HS sampler in two mountain gravel-bed streams. One set of samples was collected
conventionally by placing the sampler for 2 minutes each onto 15 evenly spaced locations across the stream
directly on the bed. The other set was collected by placing the sampler for 5 minutes each onto 6 metal ground-
plates installed flush with the streambed at about even intervals across the stream, i.e., mimicking placement of
a HS sampler onto a sill. The time of ground contact per cross-section (15 x 2 min vs. 6 x 5 min) was the same
for both sets of samples.
Results from both streams showed that the HS sampler deployed on ground-plates measured smaller transport
rates than the one deployed directly on the bed. The difference was most pronounced for the lowest flows and
more pronounced for gravel than for sand bedload. At 50% of bankfull flow, gravel transport rates obtained when
the sampler was deployed on the bed was 3 times greater than on the ground-plates at one stream and 150
times greater at the other. At near bankfull flow, transport rates from both deployments yielded similar results.
The difference in sampling results can be explained as a function of transport rates. Both deployment versions
yielded similar results for transport rates larger than 10 g/m/s because bed interactions contribute only a minor
amount to the total sample volume. At low transport rates, these interactions dominate the sampling outcome,
such that at rates of 1 and 0.1 g/m/s, the HS deployed on the bed yielded transport rates 1 and 3 orders of
magnitude above those collected with the HS sampler deployed on ground-plates.
Because deployment of the HS on ground-plates eliminates bed interaction and its distorted transport rates, an
adjustment factor (correction function) is proposed for transport rates measured with the HS sampler set directly
on a coarse gravel bed. A correction of sampling results measured during low transport would enable more
accurate calibration of site specific models when only low flow measurements are available.
DE: 1825 Geomorphology: fluvial (1625)
DE: 1846 Model calibration (3333)
DE: 1856 River channels (0483, 0744)
DE: 1862 Sediment transport (4558)
DE: 1895 Instruments and techniques: monitoring
SC: Hydrology [H]
MN: 2007 Fall Meeting