HR: 0800h
AN: H51C-0646 [Abstracts]
TI: Site Specific Evaluation of Multisensor Capacitance Probes
AU: Rowland, R A
EM: Randy.Rowland@ars.usda.gov
AF: USDA-ARS-BA-ANRI-EMSL, Bldg. 173,BARC-EAST, Powder Mill Road, Beltsville, MD
20705, United States
AU: * Guber, A K
EM: Andrey.Guber@ars.usda.gov
AF: USDA-ARS-BA-ANRI-EMSL, Bldg. 173,BARC-EAST, Powder Mill Road, Beltsville, MD
20705, United States
AU: * Guber, A K
EM: Andrey.Guber@ars.usda.gov
AF: Department of Environmental Sciences, University of California, A135 Bourns Hall,
Riverside, CA 92521, United States
AU: Pachepsky, Y
EM: Yakov.Pachepsky@ars.usda.gov
AF: USDA-ARS-BA-ANRI-EMSL, Bldg. 173,BARC-EAST, Powder Mill Road, Beltsville, MD
20705, United States
AU: Gish, T J
EM: Timothy.Gish@ars.usda.gov
AF: USDA-ARS-HRSL, Bldg.007, Baltimore Avenue, BARC-WEST, Beltsville, MD 20705, United States
AU: Daughtry, C S
EM: Craig.Daughtry@ars.usda.gov
AF: USDA-ARS-HRSL, Bldg.007, Baltimore Avenue, BARC-WEST, Beltsville, MD 20705, United States
AB:
Multisensor capacitance probes (MCPs) are widely used for measuring soil water content (SWC) at the field
scale. Although manufacturers supply a generic MCP calibration, many researchers recognize that MCPs should
be calibrated for specific field conditions. MCPs measurements are typically associated with small soil volumes,
and are subsequently scaled up to the plot or field scale. Research is needed to understand how representative
are these measurements for water monitoring studies that operate with the elementary area from one to tens
square meters. The objectives of this study were: (a) to test the accuracy of SWC field measurements using
generic and laboratory MCP calibrations; (b) to test applicability of a single MCP calibration for SWC
measurements at different depths; and (c) to compare the accuracy of two and three-parameter equations using
scaled frequency (SF). Four 1x1 m plots were equipped with MCPs to measure SWC at 9 depths at the OPE3
USDA-ARS research site at Beltsville, MD. Within each plot, three undisturbed soil cores were taken with a 100
cm3 soil auger. SWC sampling was made on three different dates when soil water contents were distinctly
different. To compare MCP measurements with observed SWC, the SF was converted into SWC using: (a) the
manufacturer generic calibration; and (b) calibration obtained in laboratory for a mesic Aquic Hapludult soil.
Parameters of three different calibration equations were also obtained by fitting the equations to the water
contents measurements at the plots. This fit was done: (a) for all observations regardless the depth, (b) for
observations at each genetic horizon, and (c) for each depth separately. Results show that the manufacturer and
the laboratory calibrations provided a satisfactory fit to the field-measured SWC at depths of 30, 40 and 50 cm.
The fit was about two times less accurate at depths of 10, 20, 60, 70 80 and 90 cm. A minor improvement was
obtained at depths of 10 and 20 cm after calibration equations were parameterized with observations from all
depths pooled together. A significant improvement (P<0.02) in accuracy of MCP measurements for depths of
10, 20, 60 and 70 cm was obtained after SWC data were grouped into subsets either according to soil genetic
horizon or according to depth. The three-parameter calibration equations did not improve accuracy compared to
two-parameter calibration equations. Overall, more accurate measurements of SWC in a layered soil using MCPs
could be obtained by employing site and depth-specific relationships between SF and plot-averaged water
contents.
DE: 1866 Soil moisture
DE: 1875 Vadose zone
DE: 1895 Instruments and techniques: monitoring
SC: Hydrology [H]
MN: 2007 Fall Meeting