HR: 0800h
AN: V41C-0721 [Abstracts]
TI: Development of Three-dimensional Stress Imaging around Mineral Inclusions in Diamond
AU: * Odake, S
EM: odk@eqchem.s.u-tokyo.ac.jp
AF: Geochemical Laboratory, Graduate School of Science, The University of Tokyo, 7-3-1
Hongo Bunkyo-ku, Tokyo, 113-0033, Japan
AU: Fukura, S
EM: fukura@eqchem.s.u-tokyo.ac.jp
AF: Geochemical Laboratory, Graduate School of Science, The University of Tokyo, 7-3-1
Hongo Bunkyo-ku, Tokyo, 113-0033, Japan
AU: Kagi, H
EM: kagi@eqchem.s.u-tokyo.ac.jp
AF: Geochemical Laboratory, Graduate School of Science, The University of Tokyo, 7-3-1
Hongo Bunkyo-ku, Tokyo, 113-0033, Japan
AU: Zedgenizov, D A
EM: zed@uiggm.nsc.ru
AF: Institute of Mineralogy and Petrography, pr. ak. Koptyuga 3, Novosibirsk, 630090, Russian
Federation
AB:
\hspace*{5mm}Most natural diamonds trap the mantle minerals and/or fluids as inclusions during its formation
in the Earth's interior. Residual stress of diamond can be measured using micro-Raman spectroscopy, as
Raman peak of diamond shifts to higher wavenumber when pressure is applied. Two-dimensional Raman
mapping of diamond samples have disclosed the stress distribution around mineral inclusions. Due to the
anisotropic elastic properties of minerals, however, three-dimensional Raman mapping is necessary for detailed
and precise estimations of stress distributions. In the present study, we aimed at three-dimensional visualization
of stress distribution using micro Raman spectroscopy. By measuring residual stresses around at least two
mineral species with different bulk modulei and thermal expansivitivties, pressure and temperature when the
inclusions were trapped in the diamond can be estimated.
\hspace*{5mm}Raman spectra of diamond were measured using a confocal Raman microscope equipped with
an automatic X-Y-Z stage. High spectroscopic resolution is required for measuring subtle difference (c.a. 0.1
cm-1) in residual stresses in diamond. Furthermore, high stability of spectrometer is also required because
it takes long time to obtain three-dimensional mapping. Our previous studies revealed that peak position of
Raman spectra contained the periodic oscillation of the peak positions with amplitude of 0.15 cm-1
synchronized the temperature regulation. In the present study, neon atomic lines for the wavenumber standard
were collected into the spectrometer simultaneously with the Raman spectrum of samples.
\hspace*{5mm}The studied sample was from Internationalnaya pipe (Russia) and contains olivine and
chromites as inclusions. The sample was polished to optical grade and a volume containing a couple of
inclusions were scanned three dimensionally. By digitizing the Raman shift of diamond, stress distribution
around the inclusions can be three-dimensionally visualized and the difference in the maximum residual
pressures surrounding mineral inclusions between olivine and chromite were revealed, respectively. Using the
obtained maximum residual pressures, the compressibilities and thermal expansivities of diamond and
inclusions, source temperature and pressure were estimated. The obtained P-T value was in the stability field of
diamond.
DE: 1000 GEOCHEMISTRY
DE: 1094 Instruments and techniques
DE: 3934 Optical, infrared, and Raman spectroscopy
SC: Volcanology, Geochemistry, Petrology [V]
MN: 2007 Fall Meeting