HR: 1400h
AN: SA53A-01 [Abstracts]
TI: Important Considerations When Using Hydroxyl Airglow Measurements to Determine Climate
Trends of the Mesopause Region.
AU: Burns, G
EM: gary.burns@aad.gov.au
AF: Australian Antarctic Division, 203 Channel Hwy, Kingston, TAS 7050, Australia
AU: * French, J
EM: john.french@aad.gov.au
AF: Australian Antarctic Division, 203 Channel Hwy, Kingston, TAS 7050, Australia
AB:
Spectral calibrations, airglow and possibly auroral contaminations, solar and telluric absorption features and the
selection of transition probabilities can all influence rotational temperatures derived from measurements of
hydroxyl airglow intensities. Consideration and examples are given of these influences. Measurements and
analyses are outlined for data checking that should be undertaken if a hydroxyl airglow data set is to be used to
determine climate trends.
Multiple spectral calibrations should be conducted throughout the observing period, with regular inter-
comparisons to other calibration sources also required. Uncertainties in spectral calibrations should be
expressed as a temperature equivalent.
Sufficient spectral scans at maximum resolution should be obtained under all extreme observing conditions (at
the lowest solar depression angle operated both morning and night, moon and cloud both separately and
combined, aurora and under conditions of enhanced atomic oxygen airglow, and under clear sky conditions but
with high atmospheric water vapour content) so that an uncertainty for the derived rotational temperatures can be
determined for the established data selection criteria.
Once the varying emission and absorption features for the hydroxyl region of interest at your site are understood
for the observing site, then the spectral resolution of the observing instrument can be reduced to increase
temporal resolution with reasonable confidence. This confidence should be tested by investigating the average
rotational temperatures derived from all possible line intensity ratios under the extreme observing conditions
noted. If a spectral-fitting rotational temperature determination is used, the residuals from the fit should be
summed and similarly examined.
Hydroxyl measurements provide a cost effective means of monitoring the temperature of the climate-sensitive
mesopause region on an almost nightly basis. If care is taken, they provide a valuable data set for investigating
climate change.
UR: http:www.aad.gov.au
DE: 0310 Airglow and aurora
DE: 1694 Instruments and techniques
DE: 3305 Climate change and variability (1616, 1635, 3309, 4215, 4513)
SC: SPA-Aeronomy [SA]
MN: 2007 Joint Assembly