Schaefer_K1979_Signals 5V and GND Output: Input Pwr OK Hi = Input Voltage OK Lo = Input Voltage out of range DC Output OK Hi = Output Voltage OK Lo = Output Voltage out of range Over Voltage Hi = Overvoltage shutdown is not activated Lo = Overvoltage shutdown is tripped. Latching Signal. Over Temperature Hi = Over temperature shutdown is not activated Lo = Over temperature shutdown is tripped. Latching Signal. Over Current Hi = Over current shutdown not activated Lo = Over current shutdown is tripped. Latching Signal. Input: Inhibit ( Remote On/Off Ctrl) Hi = Power supply is ON Lo = Power supply is OFF Function: A latched signal can be reset by cycling the remote On/Off control signal. 3 May 2022 Convo w/ Dave French: 0 Status lines should go thru opto-isolator then to R Pi AND front panel leds directly 0 Add a " heartbeat " status light 0 Add a front panel R Pi reset button 0 Use a latching relay to control the K1979 ON / OFF 0 Use a second 5V p/s, diode OR'd for K1979 ON / OFF