Schaefer_K1979_Signals 5V and GND Output: Input Pwr OK Hi = Input Voltage OK Lo = Input Voltage out of range DC Output OK Hi = Output Voltage OK Lo = Output Voltage out of range Over Voltage Hi = Overvoltage shutdown is not activated Lo = Overvoltage shutdown is tripped. Latching Signal. Over Temperature Hi = Over temperature shutdown is not activated Lo = Over temperature shutdown is tripped. Latching Signal. Over Current Hi = Over current shutdown not activated Lo = Over current shutdown is tripped. Latching Signal. Input: Inhibit ( Remote On/Off Ctrl) Hi = Power supply is ON Lo = Power supply is OFF Function: A latched signal can be reset by cycling the remote On/Off control signal. 3 May 2022 Convo w/ Dave French: 1 HDWRE Status lines should go thru opto-isolator then to R Pi AND front panel leds directly 1 Python 1 HDWRE Add a " heartbeat " status light Change J2 1 Python 1 HDWRE Add a front panel R Pi reset button 1 HDWRE Use a latching relay to control the K1979 ON / OFF 1 Python 1 HDWRE Use a second 5V p/s, diode OR'd for K1979 ON / OFF 15 May 2022 1 "ON CMD" LED should be fed from the relay, thru opto-isolator 1 signal " ON_CMD_LED " ( active high ) needs to go to the Raspberry Pi 2 Jun 2022 1 Change GPIO_ON ( 2 ) to 17 -- Header 11 1 Sch 1 PCB 1 Change GPIO_OFF ( 3 ) to 27 -- Header 13 1 Sch 1 PCB