(ExpressProject ""
  (ProjectVersion "19981106")
  (ProjectType "PCB")
  (Folder "Design Resources"
    (Folder "Library"
      (File "c:\orcad_data\kecy_orcad_lib.olb"
        (Type "Schematic Library"))
      (File ".\10020537.olb"
        (Type "Schematic Library")))
    (File ".\co2 louver feedback board.dsn"
      (Type "Schematic Design"))
    (BuildFileAddedOrDeleted "x")
    (CompileFileAddedOrDeleted "x")
    (NoModify)
    (DRC_Scope "0")
    (DRC_Action "0")
    (DRC_Create_Warnings "FALSE")
    (DRC_Check_Ports "FALSE")
    (DRC_Check_Off-Page_Connectors "FALSE")
    (DRC_Identical_References "TRUE")
    (DRC_Type_Mismatch "TRUE")
    (DRC_Report_Ports_and_Off-page_Connectors "FALSE")
    (DRC_SDT_Compatibility "FALSE")
    (DRC_Report_Off-grid_Objects "FALSE")
    (DRC_Check_Unconnected_Nets "TRUE")
    (DRC_Check_for_Misleading_TAP "FALSE")
    (DRC_Visible_Power_pins "FALSE")
    (DRC_Report_Netnames "FALSE")
    (DRC_View_Output "FALSE")
    (DRC_Report_File
       "C:\PROJECTS\FOCE\CO2\LOUVER BOARD\CO2 LOUVER FEEDBACK BOARD.DRC")
    (BOM_Scope "0")
    (BOM_Mode "0")
    (BOM_Report_File
       "C:\PROJECTS\FOCE\CO2\LOUVER BOARD\CO2 LOUVER FEEDBACK BOARD - Line Item.BOM")
    (BOM_Merge_Include "FALSE")
    (BOM_Property_Combine_7.0
       "{Reference}\t{Value}\t{Quantity}\t{Manufacturer}\t{Manuf PN}\t{Supplier}\t{Supplier PN}\t{Package}\t{Description}\t{PCB Footprint}")
    (BOM_Header
       "Reference\tValue\tQuantity\tManufacturer\tManuf PN\tSupplier\tSupplier PN\tPackage\tDescription\tPCB Footprint")
    (BOM_Include_File
       "C:\PROJECTS\FOCE\CO2\LOUVER BOARD\CO2 LOUVER FEEDBACK BOARD.INC")
    (BOM_Include_File_Combine_7.0 "{Item}\t{Quantity}\t{Reference}\t{Value}")
    (BOM_One_Part_Per_Line "FALSE")
    (Open_BOM_in_Excel "FALSE")
    (BOM_View_Output "FALSE")
    (Netlist_TAB "0"))
  (Folder "Outputs"
    (File ".\co2 louver feedback board.drc"
      (Type "Report"))
    (File ".\co2 louver feedback board.bom"
      (Type "Report"))
    (File ".\co2 louver feedback board - line item.bom"
      (Type "Report"))
    (File ".\allegro\pstxnet.dat"
      (Type "Report")
      (DisplayName "pstxnet.dat"))
    (File ".\allegro\pstxprt.dat"
      (Type "Report")
      (DisplayName "pstxprt.dat"))
    (File ".\allegro\pstchip.dat"
      (Type "Report")
      (DisplayName "pstchip.dat")))
  (Folder "Referenced Projects")
  (PartMRUSelector)
  (GlobalState
    (FileView
      (Path "Design Resources")
      (Path "Design Resources" "Library")
      (Path "Outputs"))
    (HierarchyView)
    (Doc
      (Type "COrCapturePMDoc")
      (Frame
        (Placement "44 0 1 -1 -1 -4 -30 0 200 0 472"))
      (Tab 0))
    (Doc
      (Type "COrSchematicDoc")
      (Frame
        (Placement "44 2 3 -1 -1 -4 -30 22 2225 29 855")
        (Scroll "-5 -163")
        (Zoom "53")
        (Occurrence "/"))
      (Path
         "J:\PCB_LAYOUT\COMPLETED\10020537_LOUVER-FEEDBACK\CO2 LOUVER FEEDBACK BOARD.DSN")
      (Schematic "SCHEMATIC1")
      (Page "01 - Upper Switches")))
  (MPSSessionName "jrosal")
  (ISPCBBASICLICENSE "false"))