(    Allegro Netrev Import Logic                                      )
(                                                                     )
(    Drawing          : 11021167rA_BatteryStatusBRD.brd               )
(    Software Version : 16.6S050                                      )
(    Date/Time        : Thu Jun 25 15:00:07 2015                      )
(                                                                     )
(---------------------------------------------------------------------)


------ Directives ------------

Ripup etch:                  No
Ripup delete first segment:  No
Ripup retain bondwire:       No
Ripup symbols:               Always
Missing symbol has error:    No
DRC update:                  Yes
Schematic directory:         '.'
Design Directory:            '.'
Old design name:             'J:/PCB_Layout/Open_Work_Space/11021167-Battery-Status-Board/allegro/11021167rA_BatteryStatusBRD.brd'
New design name:             'J:/PCB_Layout/Open_Work_Space/11021167-Battery-Status-Board/allegro/11021167rA_BatteryStatusBRD.brd'

CmdLine: netrev -$ -i . -y 1 -q netrev_constraint_report.xml J:/PCB_Layout/Open_Work_Space/11021167-Battery-Status-Board/allegro/#Taaaaal10492.tmp

------ Preparing to read pst files ------

Starting to read ./pstchip.dat 
   Finished reading ./pstchip.dat (00:00:00.06)
Starting to read ./pstxprt.dat 
   Finished reading ./pstxprt.dat (00:00:00.00)
Starting to read ./pstxnet.dat 
   Finished reading ./pstxnet.dat (00:00:00.01)

------ Oversights/Warnings/Errors ------


#1   WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]

ERROR(SPMHNI-196): Symbol 'DIOAD1270W125L950D530B' for device 'DIODE_DIOAD1270W125L950D530B_DI' has extra pin 'C'.

ERROR(SPMHNI-196): Symbol 'DIOAD1270W125L950D530B' for device 'DIODE_DIOAD1270W125L950D530B_DI' has extra pin 'A'.

ERROR(SPMHNI-195): Symbol 'DIOAD1270W125L950D530B' for device 'DIODE_DIOAD1270W125L950D530B_DI' is missing pin '2'.

ERROR(SPMHNI-195): Symbol 'DIOAD1270W125L950D530B' for device 'DIODE_DIOAD1270W125L950D530B_DI' is missing pin '1'.

#1   ERROR(SPMHNI-191): Device/Symbol check error detected.

ERROR(SPMHNI-195): Symbol 'MNT_C500H230' for device 'CON1_MNT_C500H230_MNHOLE/0.23"' is missing pin '1'.

------ Library Paths ------
MODULEPATH =  . 
           C:/Cadence/SPB_16.6/share/local/pcb/modules 

PSMPATH =  . 
           //WATER/Allegro_Library/Symbols 
           //WATER/Allegro_Library/FORMAT 
           //WATER/Allegro_Library/Pads 

PADPATH =  . 
           //WATER/Allegro_Library/Pads 
           J:/PCB_Layout/Layout_Libraries/LIBRARIES/CNC_PAD-LIBRARY/ 


------ Summary Statistics ------


#2   Run stopped because errors were detected

netrev run on Jun 25 15:00:07 2015
   DESIGN NAME : '11021167-BSB1'
   PACKAGING ON Oct 15 2014 05:53:32

   COMPILE 'logic'
   CHECK_PIN_NAMES OFF
   CROSS_REFERENCE OFF
   FEEDBACK OFF
   INCREMENTAL OFF
   INTERFACE_TYPE PHYSICAL
   MAX_ERRORS 500
   MERGE_MINIMUM 5
   NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
   NET_NAME_LENGTH 24
   OVERSIGHTS ON
   REPLACE_CHECK OFF
   SINGLE_NODE_NETS ON
   SPLIT_MINIMUM 0
   SUPPRESS   20
   WARNINGS ON

  2 errors detected
 No oversight detected
  1 warnings detected

cpu time      0:01:28
elapsed time  0:00:01

SPMHNI-192:
This is a general warning that is normally paired with another message. Check the secondary message for more detail.