(    Allegro Netrev Import Logic                                      )
(                                                                     )
(    Drawing          : 10021142-05-06rA.brd                          )
(    Software Version : 16.6-2015S055                                 )
(    Date/Time        : Wed Sep 02 11:31:31 2015                      )
(                                                                     )
(---------------------------------------------------------------------)


------ Directives ------------

Ripup etch:                  No
Ripup delete first segment:  No
Ripup retain bondwire:       No
Ripup symbols:               Always
Missing symbol has error:    No
DRC update:                  Yes
Schematic directory:         '.'
Design Directory:            '.'
Old design name:             'J:/PCB_Layout/Open_Work_Space/11021186-07-A_CCE-BATTERY-SPHERE-PCB/Allegro_10021142-05-06/10021142-05-06rA.brd'
New design name:             'J:/PCB_Layout/Open_Work_Space/11021186-07-A_CCE-BATTERY-SPHERE-PCB/Allegro_10021142-05-06/10021142-05-06rA.brd'

CmdLine: netrev -$ -i . -y 1 -q netrev_constraint_report.xml J:/PCB_Layout/Open_Work_Space/11021186-07-A_CCE-BATTERY-SPHERE-PCB/Allegro_10021142-05-06/#Taaaaac03940.tmp

------ Preparing to read pst files ------

Starting to read ./pstchip.dat 
   Finished reading ./pstchip.dat (00:00:00.09)
Starting to read ./pstxprt.dat 
   Finished reading ./pstxprt.dat (00:00:00.00)
Starting to read ./pstxnet.dat 
   Finished reading ./pstxnet.dat (00:00:00.03)

------ Oversights/Warnings/Errors ------


#1   WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]

WARNING(SPMHNI-194): Symbol 'CAPC3216X185N' used by RefDes C10 for device 'CAP_CAPC3216X185N_DISCRETE_0.47' not found in PSMPATH or must be "dbdoctor"ed.

------ Library Paths ------
MODULEPATH =  . 
           C:/Cadence/SPB_16.6/share/local/pcb/modules 

PSMPATH =  . 
           //WATER/Allegro_Library/Symbols 
           //WATER/Allegro_Library/FORMAT 
           //WATER/Allegro_Library/Pads 

PADPATH =  . 
           //WATER/Allegro_Library/Pads 
           J:/PCB_Layout/Layout_Libraries/LIBRARIES/CNC_PAD-LIBRARY/ 


------ Summary Statistics ------


netrev run on Sep 2 11:31:31 2015
   DESIGN NAME : 'CCE_BINWIRING'
   PACKAGING ON Aug  3 2015 18:16:55

   COMPILE 'logic'
   CHECK_PIN_NAMES OFF
   CROSS_REFERENCE OFF
   FEEDBACK OFF
   INCREMENTAL OFF
   INTERFACE_TYPE PHYSICAL
   MAX_ERRORS 500
   MERGE_MINIMUM 5
   NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
   NET_NAME_LENGTH 24
   OVERSIGHTS ON
   REPLACE_CHECK OFF
   SINGLE_NODE_NETS ON
   SPLIT_MINIMUM 0
   SUPPRESS   20
   WARNINGS ON

 No error detected
 No oversight detected
  1 warnings detected

cpu time      0:03:04
elapsed time  0:00:01

SPMHNI-192:
This is a general warning that is normally paired with another message. Check the secondary message for more detail.