From meed@mbari.org Fri Nov 18 12:10 PST 1994
Received: from wave.mbari.org by barnacle.mbari.org with SMTP
	(1.38.193.4/16.2) id AA01349; Fri, 18 Nov 1994 12:10:52 -0800
Return-Path: <meed@mbari.org>
Received: from reef.mbari.org by wave.mbari.org with SMTP
	($Revision: 1.37.109.9 $/16.2) id AA152502634; Fri, 18 Nov 1994 12:10:50 -0800
Received: by reef.mbari.org
	(1.38.193.4/16.2) id AA20892; Fri, 18 Nov 1994 12:10:50 -0800
From: Ed Mellinger <meed@mbari.org>
Subject: Re: VB Software (fwd)
To: pean@wave.mbari.org (Andrew Pearce)
Date: Fri, 18 Nov 94 12:10:50 PST
Cc: kiwi@wave.mbari.org (William Kirkwood), meed@wave.mbari.org (Ed Mellinger)
In-Reply-To: from "Andrew Pearce" at Nov 18, 94 11:33 am
Mailer: Elm [revision: 70.85]
Status: RO

> One item I need 
> from you is the specification and a drawing (or a part) for the
> temperature probe you want to use. I'll design a small housing
> to include it and the water height gauge, the seperation will be
> minimal that way.
> 

Life will be easiest if we use the quasi-standard AD592 temp-to-current
transducer.  It comes in a TO-92 package (small plastic transistor w/ 3
skinny leads).  We can power it off the 12V that we run the water height
sensor off (which will also be the 12V for the Falmouth Pressure).  The
temp sensor will need one return lead for it's output current.  (That
should make a total of five for this housing, four for the height sensor
and one for the temp sensor.

If there is room in the housing I'd like to include a transient
suppressor zener and possibly a bypass capacitor, both small devices
also.  Let me know and I'll dig up drawings for all three items.